About the interval when installing EWF next to each other
When installing EWF next to each other, how much interval needed between?
If EWF are installed next to each other, they may interfere each other and cause a malfunction. Therefore, leave an interval as twice as the directivity angle.
The interval can be calculated below.
Interval = (tan directional angle x maximum working distance) x 2 times
EWF-1E series Direction angle 1 ° Interval (mm) = 35 x distance (m)
EWF-0E series directional angle 1.4 ° interval (mm) = 48 x distance (m)
Also, make sure that the light reception level is not lit by the light from the devices nearby while the light of the communication partner is blocked.
Relation
-
Does the mounting bracket come with when purchasing the EWF?
-
Can EWF-0V be used with SSCNET III / H?
-
What is the difference between EWF-0EA-01 and EWF-1E-N?
-
Are there any optical data transmission devices that support UL standards?
-
There are normal mode, master mode, and slave mode. How should I use the operation mode properly?
FAQ's Category
- Scanning Range Finder (Data Output Type)
- Scanning Range Finder (Area Configuration Type)
- Photoelectric Switch
- 3D LiDAR
- Area Configuration Type
- Optical Data Transmission Device
- Sensor for Iron and Steel Industry
- Area Configulation Type
- Optical Remote Control Device
- Auto Counter
- Sensor for Textile Industry
- Application
- Laser Range Finder
FAQ's Tag
- PEY
- PA-S
- PL1
- LAD
- LX1
- DMH
- PNX
- PDL
- DM
- post_tag-195
- BRS
- PK7
- EP1
- PA
- AC
- PD
- PR
- LX2
- LAV
- post_tag-163
- CWF
- RS controller
- S-20
- PH-DX
- MC-A201
- PCF
- BNC
- DMC
- PA-SC2
- DWF
- PB9
- PD5
- ISL
- DME
- PG
- PFX
- KRG
- ISP
- DMF
- DMG
- EWF
- DMS
- FHM
- LA
- HMPD
- FBX
- UXM
- PBS
- KAD
- BWF
- DMJ
- PHF
- PHE
- PX1
- UAM
- URM
- UST
- YVT
- PGL
- LEX
- MFG
- MBX
- VMH
- FG
- PLX
- FC
- DC
- BRC
- PEX
- UTM
- PH
- HSA
- EH8
- MBF
- URG
- UBG
- UGM
- DMM