FAQ
Archive カテゴリ:Scanning Range Finder (Area Configuration Type)
-
Why is the spread of the light beam different from the front and the side of the LiDAR?
-
What is the scratch resistance of UTM-30LX-EW before and after hard coating?
-
I am using UAM in ROS, but if I change the model to UST or URM, is it possible to substitute the software as it is?
-
What is the area input delay of UAM-05LP-T301?
-
Why does the signal of output 3 become uncertain when the area input of PBS-03JN is switched (including defects)?
-
If PBS-03JN is affected by ambient light or vibration, will the malfunction output basically turn off and outputs 1 to 3 also turn off?
-
Is area data written to PBS-03JN at the time of shipment?
-
Please tell me about the painting specifications of UXM-30-BK01.
-
What is the software called the function setting tool of UXM-30LXH-EHA for?
-
How can I switch the area of UAM-05LP-T301?
-
Why is the point cloud data not displayed even when YVT is connected to the software?
-
Is it possible to monitor EWF-0 / 1E-N with a PLC app?
-
Are the vibration / shock resistance described in URM specifications implemented based on some international standards? If so, please disclose it. Also, are the standards
also applied to other products? -
What is the maximum voltage and current for the output of the UST-05LN?
-
Do you have a CD-R of PBS-03JN application software?
-
Please tell me about the weather resistance of the cable.
-
What are the specifications of UAM's Ethernet cable?
-
Is there anything I can do if I don't know the IP address of the range sensor?
-
Is it possible to use the range sensor with Windows pro?
-
Does the UST-30LC have an enclave area function?
-
Two sets of LAVs are installed adjacent to each other at 1m intervals. The output response time of one of them varies, but It is said that it will be delayed by 3 to 4 seconds. Does it mean that there is interference light from other than the LAV that is wired synchronously? With the dark ON / SYC ON setting, the light reception level is gradually lowered from 8 to 0. Does this mean that the light cannot be blocked instantly?
-
Does the PB9-13AN-01 application support the PBS application?
-
What is the minimum detection object for PBS?
Is a fingertip detectable? -
URG driver cannot be installed on Windows Embedded Standard 7
-
Is it possible to use only one output of UST-05LN?
-
Is it possible to overwrite the data of the old UST-05LN to a new UST-05LN?
-
Does the laser beam of UST-05LN decrease due to deterioration over time?
-
What is the leakage current of URM and UST?
-
I got a UAM error number 89. The error number was not mentioned in the instruction manual.
What kind of error is it? -
Checking the input / output circuits of PNX-705R [Light On] and PNX-705L [Dark On], both are C contacts, so if you use both gray and white lines, they will be light on, and if you use black and white lines, they will be dark on. I feel like I don't need the concept of light-on and dark-on, but how about it?
-
How much is DMS-HB1-Z01 weight?
-
What is the difference between PBS-03JN and PBS-03JN-05?
-
When using with multi-echo function, how much rainfall can be detected with UST-30LX?
-
Does the range sensor (PBS / UST / UAM) use OSSD?
-
The UST-30LX has multi-echo support and stain resistance, but what about water droplet adhesion?
-
Will water droplets on the surface of the UST-10LX optical window affect data acquisition?
-
I'm running UST using a battery.
The battery voltage became low and the UST failed output.
How low is the voltage / current before the failure output is triggered?
Do you know the exact value? -
What happens to the slave side when an area switching signal is input to the slave side while using the master-slave function of UAM-05LP-T301?
-
When was the time stamp acquired?
-
When I try to connect to the sensor from Linux, I should be accessing the correct serial port, but I can't.
-
Is it possible to acquire data from multiple sensors at the same time?
-
How much communication data does the sensor have?
-
When I install the USB driver and connect the sensor, the mouse cursor moves randomly and clicks on various places.
-
The scan cycle of UTM-30LX-EW should be 25ms, but sometimes it becomes 50ms.
-
UST-05LN causes chattering. Is there any countermeasure?
-
Even if I set the area of UST-30LC and write it, it is not reflected even if I check it in monitor mode. Why?
-
Please tell me about the difference in UST series detection distance.
-
What is the vertical resolution of YVT?
-
I want to check the continuity of the tester with a wiring chuck in advance in order to light up the lamp using the output 1 of the URM-40LC-EW. Please tell me how to connect COM, output 1 and load correctly.
-
When using the master-slave function of UAM-05LP-T301, what happens on the slave side when an area switching signal is input to the slave side?
-
What is UAM's additional safety distance?
-
Is there any countermeasure for UAM false detection?
-
If a highly reflective background is used as the measured target, should I offset the measured value uniformly by "200 mm"? Or does the distance differ depending on the type of high-reflective object?
-
When the UST-05LN is started. the inrush current is 400mA. How long does the inrush current flow?
-
How much is the weight of the rear mounting bracket and cover bracket of the UGM?
-
Is it possible to detect black objects with UBG-05LN?
-
I get a UAM error number 85. What should I do?
-
Is it possible to set 2 points on the same step when setting the area?
-
Please tell me about the output residual voltage of URM and UST.
-
What is the detection range of UBG-E2R-FX? Is it still in production?
-
I get an optical window / short-distance error when using the muting function. Is it normal that short-distance error occurs if there is an object near the sensor even in muting mode?
The cause is probably smoke. Smoke will be a trigger of the short-distance error. -
Is it possible to transfer the data of UAM-02LP to UAM-05LP?
-
Should the shielded wire of PBS-03JN be connected to ground?
-
Which side of the PBS optical window is the light emitting side, top or bottom?
-
Is it possible to use a USB conversion cable when setting the area?
-
Is there an output to notify the PLC side when there is an abnormality in UAM?
-
ー
-
Please tell us the UL File No and product category.
Also, is the optional "UAM-5C02C" UL certified? -
Is it compatible with Windows 10?
-
How much is the light beam of UAM?
-
Do I have to connect all the wires when extending the UAM cable?
-
What happens if the light is blocked?
-
What kind of output is synchronous output?
-
Do you need a exclusive driver for Ethernet type?
-
I connected to a PC, but it does not recognize the sensor. What should I do.
-
The optical window has become dirty. Please tell me how to clean it.
-
I have connected the output COM, but there is no output. What should I do.
-
What is the difference between LX mode and LA mode?
-
What are the start-up conditions for the heater?
-
The URG-04LX has a range of 60 to 4095 mm and a range of 20 to 5600 mm. Does this mean that the range of 60 mm or less does not meet the range of accuracy described in the product specifications?
2. In that case, can you tell us what kind of response you will get in the range of 20mm to 60mm? -
What is the UAM additional safety distance?
-
Why is air in the waveguide between the amplifier and antenna of MBX-301A?
-
The PBS configured area has disappeared.
The power is on and the green indicator light is on, but it doesn't detect any obstacles entering the area. -
How much can the cable be bent?
-
A white connector is attached at the time of delivery. Is this for making connection?
-
What is response time?
-
What is OOSD output?
-
Is it possible to change the output to NPN output?
-
Is it possible to use it without setting a protection area?
-
I created an area and wrote to the sensor, but why is it output even though there is no object in the area?
-
What happens if On-delay / Off-delay is set?
-
Please tell me how to set the hysteresis.
-
Please tell me how to connect to the output.
-
What is the end of the RS232C connection cable for PBS?
-
When setting with the muting function, it is necessary to set a time difference but it is not possible to set them at the same time.
How much time difference should be set not to be simultaneously? -
How wide is the light beam?
-
Please tell us about the appearance (material, surface treatment, paint specifications, paint color) of the back mounting bracket and cover bracket of UGM.
-
Does it work even if power is supplied from the battery?
-
What is the conductor size of the cable?
-
I'm having trouble with reset input.
-
Where can I find the error number?
-
Are there any precautions to take when attaching a cover?
-
Is there any way to deliberately put the sensor in a malfunction state?
-
Sensor erroneously detect that there is an obstacle even though there is no object. Why it happens?
-
Please tell me about the output logic of the Scanning Range Finder.
-
How many millimeters does a short-distance error occur at?
-
Please tell me how to use the app.
-
How many meters can the cable be extended?
-
Is it possible to install the sensor upside down?
-
Sensors Interfere with each other. Please tell me the measures.
-
I want to connect to a PC and edit the area with the application, but the sensor is not recognized.
What should i do? -
The light from the sensor is affecting other devices. Is there any measures?
-
Is there any software to transfer area data from PBS-03JN to UST-05LN?
-
What is contamination detection?
-
Do the UAM-05LP-T301 brackets come with the screws?
FAQ's Category
- Scanning Range Finder (Data Output Type)
- Scanning Range Finder (Area Configuration Type)
- Photoelectric Switch
- 3D LiDAR
- Area Configuration Type
- Optical Data Transmission Device
- Sensor for Iron and Steel Industry
- Area Configulation Type
- Optical Remote Control Device
- Auto Counter
- Sensor for Textile Industry
- Application
- Laser Range Finder
FAQ's Tag
- PEY
- PA-S
- PL1
- LAD
- LX1
- DMH
- PNX
- PDL
- DM
- post_tag-195
- BRS
- PK7
- EP1
- PA
- AC
- PD
- PR
- LX2
- LAV
- post_tag-163
- CWF
- RS controller
- S-20
- PH-DX
- MC-A201
- PCF
- BNC
- DMC
- PA-SC2
- DWF
- PB9
- PD5
- ISL
- DME
- PG
- PFX
- KRG
- ISP
- DMF
- DMG
- EWF
- DMS
- FHM
- LA
- HMPD
- FBX
- UXM
- PBS
- KAD
- BWF
- DMJ
- PHF
- PHE
- PX1
- UAM
- URM
- UST
- YVT
- PGL
- LEX
- MFG
- MBX
- VMH
- FG
- PLX
- FC
- DC
- BRC
- PEX
- UTM
- PH
- HSA
- EH8
- MBF
- URG
- UBG
- UGM
- DMM