FAQ
Archive タグ:PBS
-
Does it work even if power is supplied from the battery?
-
How much can the cable be bent?
-
A white connector is attached at the time of delivery. Is this for making connection?
-
What is response time?
-
I created an area and wrote to the sensor, but why is it output even though there is no object in the area?
-
What happens if On-delay / Off-delay is set?
-
Please tell me how to set the hysteresis.
-
Please tell me how to connect to the output.
-
Is it possible to install the sensor upside down?
-
What is the end of the RS232C connection cable for PBS?
-
Is it possible to use a USB conversion cable when setting the area?
-
What is contamination detection?
-
Are there any precautions to take when attaching a cover?
-
Please tell me about the output logic of the Scanning Range Finder.
-
Sensors Interfere with each other. Please tell me the measures.
-
I want to connect to a PC and edit the area with the application, but the sensor is not recognized.
What should i do? -
Sensor erroneously detect that there is an obstacle even though there is no object. Why it happens?
-
Please tell me how to use the app.
-
Is there any way to deliberately put the sensor in a malfunction state?
-
Is it possible to use the range sensor with Windows pro?
-
If PBS-03JN is affected by ambient light or vibration, will the malfunction output basically turn off and outputs 1 to 3 also turn off?
-
Is there any software to transfer area data from PBS-03JN to UST-05LN?
-
About blocking when downloading application software
-
The light from the sensor is affecting other devices. Is there any measures?
-
Why is the spread of the light beam different from the front and the side of the LiDAR?
-
Is area data written to PBS-03JN at the time of shipment?
-
Should the shielded wire of PBS-03JN be connected to ground?
-
Do you have a CD-R of PBS-03JN application software?
-
Does the PB9-13AN-01 application support the PBS application?
-
Why does the signal of output 3 become uncertain when the area input of PBS-03JN is switched (including defects)?
-
What is the difference between PBS-03JN and PBS-03JN-05?
-
Does the range sensor (PBS / UST / UAM) use OSSD?
-
What is the minimum detection object for PBS?
Is a fingertip detectable? -
The PBS configured area has disappeared.
The power is on and the green indicator light is on, but it doesn't detect any obstacles entering the area. -
Which side of the PBS optical window is the light emitting side, top or bottom?
-
What kind of output is synchronous output?
-
I connected to a PC, but it does not recognize the sensor. What should I do.
-
The optical window has become dirty. Please tell me how to clean it.
FAQ's Category
- Scanning Range Finder (Data Output Type)
- Scanning Range Finder (Area Configuration Type)
- Photoelectric Switch
- 3D LiDAR
- Area Configuration Type
- Optical Data Transmission Device
- Sensor for Iron and Steel Industry
- Area Configulation Type
- Optical Remote Control Device
- Auto Counter
- Sensor for Textile Industry
- Application
- Laser Range Finder
FAQ's Tag
- PEY
- PA-S
- PL1
- LAD
- LX1
- DMH
- PNX
- PDL
- DM
- post_tag-195
- BRS
- PK7
- EP1
- PA
- AC
- PD
- PR
- LX2
- LAV
- post_tag-163
- CWF
- RS controller
- S-20
- PH-DX
- MC-A201
- PCF
- BNC
- DMC
- PA-SC2
- DWF
- PB9
- PD5
- ISL
- DME
- PG
- PFX
- KRG
- ISP
- DMF
- DMG
- EWF
- DMS
- FHM
- LA
- HMPD
- FBX
- UXM
- PBS
- KAD
- BWF
- DMJ
- PHF
- PHE
- PX1
- UAM
- URM
- UST
- YVT
- PGL
- LEX
- MFG
- MBX
- VMH
- FG
- PLX
- FC
- DC
- BRC
- PEX
- UTM
- PH
- HSA
- EH8
- MBF
- URG
- UBG
- UGM
- DMM